Table 7.

Magnitudes and phase angles of the components of each of the three eigenvectors when the rate derivatives are set to zero

Modeδu+δw+δq+δθ
Unstable oscillatory 0.9×10-1 (121.7°) 1.9×10-4 (64.6°) 1.5×10-1 (60.9°) 1 (0°) 
Fast subsidence 0.9×10-1 (0°) 2.2×10-4 (180°) 1.6×10-1 (180°) 1 (0°) 
Slow subsidence 1.4 (0°) 1.7×10 (0°) 1.2×10-2 (180°) 1 (0°) 
Modeδu+δw+δq+δθ
Unstable oscillatory 0.9×10-1 (121.7°) 1.9×10-4 (64.6°) 1.5×10-1 (60.9°) 1 (0°) 
Fast subsidence 0.9×10-1 (0°) 2.2×10-4 (180°) 1.6×10-1 (180°) 1 (0°) 
Slow subsidence 1.4 (0°) 1.7×10 (0°) 1.2×10-2 (180°) 1 (0°) 

δu+, δw+q+ and δθ, disturbance quantities in non-dimensional x-component and z-component of velocity,pitching rate and pitch angle, respectively.

Numbers in the parentheses are the phase angles.