Table 1.

Magnetic disturbances (in nT) produced by our PTTs (all distances relative to its centre of mass)

Distance in front of PTT (cm)
1015202530354045
Transmitting and silent transmitter         
x −271 −190 −125 −85 −49 −35 −26 −18 
y 17 207 17 225 17 229 17 230 17 239 17 239 17 239 17 242 
z 44 466 44 479 44 473 44 465 44 458 44 450 44 447 44 443 
Change in field strength         
x −260 −179 −114 −74 −38 −24 −15 <10 
y −33 −15 −11 −10 <10 <10 <10 <10 
z 26 39 33 25 18 10 <10 <10 
Distance in front of PTT (cm)
1015202530354045
Transmitting and silent transmitter         
x −271 −190 −125 −85 −49 −35 −26 −18 
y 17 207 17 225 17 229 17 230 17 239 17 239 17 239 17 242 
z 44 466 44 479 44 473 44 465 44 458 44 450 44 447 44 443 
Change in field strength         
x −260 −179 −114 −74 −38 −24 −15 <10 
y −33 −15 −11 −10 <10 <10 <10 <10 
z 26 39 33 25 18 10 <10 <10 

PTT, platform transmitter terminal.

Magnetic disturbance was measured by a high-precision three-axial flux gate magnetometer (MEDA FVM-400).

Reference values (natural field, no transmitter): x=−11; y=17,240; z=44,440, where x defines the direction towards the bill, y defines the direction perpendicular to the bill(positive to the left of the bill, negative to the right of the bill) and z defines the vertical component (positive towards the earth,negative towards the sky).

nT, nano Tesla; PTT, platform transmitter terminal.

Bold values are the magnetic disturbances from our transmitter fixed 30-33 cm from the head of the birds when flying.