Absolute systemic( Q̇ sys) and pulmonary( Q̇ pul) flows during the experimental clamping of the systemic vein (right atrial inflow) or pulmonary vein (left atrial inflow)
. | Psys=3 kPa . | . | Psys=6.5 kPa . | . | Psys=8 kPa . | . | |||
---|---|---|---|---|---|---|---|---|---|
. | Q̇ sys . | Q̇ pul . | Q̇ sys . | Q̇ pul . | Q̇ sys . | Q̇ pul . | |||
Ppul=8 kPa | |||||||||
Control | 19.3±3.1* | 2.1±0.9 | 9.9±1.6* | 4.0±1.1 | |||||
Clamp systemic vein | |||||||||
Clamp pulmonary vein | 12.3±3.2†,* | 1.7±0.7 | 4.9±1.5† | 2.6±0.7 | |||||
Ppul=6.5 kPa | |||||||||
Control | 20.5±3.7* | 7.3±1.5 | 11.4±1.2 | 11.1±0.7 | 7.3±1.5 | 9.4±0.6 | |||
Clamp systemic vein | 25.3±2.8* | 0.4±0.3† | 16.9±2.2†,* | 0.6±0.4† | 13.8±1.2* | 0.4±0.3† | |||
Clamp pulmonary vein | 10.6±3.4† | 5.2±1.4 | 2.7±1.0†,* | 10.2±1.5 | |||||
Ppul=3 kPa | |||||||||
Control | 24.7±2.3 | 27.9±3.8 | 17.6±1.8 | 27.2±3.7 | 13.3±2.0* | 25.3±3.5 | |||
Clamp systemic vein | 30.5±4.1* | 2.1±0.7† | 23.7±2.5* | 3.6±0.6† | 19.9±1.8* | 3.8±0.6† | |||
Clamp pulmonary vein | 4.4±2.2†,* | 28.5±3.3 | 1.7±0.9†,* | 29.9±2.9 |
. | Psys=3 kPa . | . | Psys=6.5 kPa . | . | Psys=8 kPa . | . | |||
---|---|---|---|---|---|---|---|---|---|
. | Q̇ sys . | Q̇ pul . | Q̇ sys . | Q̇ pul . | Q̇ sys . | Q̇ pul . | |||
Ppul=8 kPa | |||||||||
Control | 19.3±3.1* | 2.1±0.9 | 9.9±1.6* | 4.0±1.1 | |||||
Clamp systemic vein | |||||||||
Clamp pulmonary vein | 12.3±3.2†,* | 1.7±0.7 | 4.9±1.5† | 2.6±0.7 | |||||
Ppul=6.5 kPa | |||||||||
Control | 20.5±3.7* | 7.3±1.5 | 11.4±1.2 | 11.1±0.7 | 7.3±1.5 | 9.4±0.6 | |||
Clamp systemic vein | 25.3±2.8* | 0.4±0.3† | 16.9±2.2†,* | 0.6±0.4† | 13.8±1.2* | 0.4±0.3† | |||
Clamp pulmonary vein | 10.6±3.4† | 5.2±1.4 | 2.7±1.0†,* | 10.2±1.5 | |||||
Ppul=3 kPa | |||||||||
Control | 24.7±2.3 | 27.9±3.8 | 17.6±1.8 | 27.2±3.7 | 13.3±2.0* | 25.3±3.5 | |||
Clamp systemic vein | 30.5±4.1* | 2.1±0.7† | 23.7±2.5* | 3.6±0.6† | 19.9±1.8* | 3.8±0.6† | |||