SUMMARY
The position of a hydrodynamic dipole source, as encoded in a linear array of mechano-detecting neuromasts in the fish lateral line canal, was electrophysiologically investigated. Measured excitation patterns along the lateral line were compared to theoretical predictions and were found to be in good agreement. The results demonstrate that information on the position of a vibrating source from a fish is linearly coded in the spatial characteristics of the excitation pattern of pressure gradients distributed along the lateral line canal. Several algorithms are discussed that could potentially be used by a fish to decode lateral line excitation patterns, in order to localise a source and its axis of vibration. Specifically, a wavelet transform of a 1-D excitation pattern is shown to reconstruct a 2-D image of dipole sources located within a distance comparable to the body length of a fish and with a close range spatial accuracy twice the inter-neuromast distance.
Introduction
Fish possess the ability to detect moving and vibrating underwater objects using their mechanosensory lateral line organ(Dijkgraaf, 1963). The lateral line organ is an ensemble of mechanosensory units, called neuromasts. These units are present on the skin (superficial neuromasts) or are distributed in lateral line canals running along the body (canal neuromasts). In addition to its presence on the trunk, in many species the lateral line canal organ is also well distributed over the head in the so-called cephalic lateral line canals (Coombs et al., 1988; Webb, 1989). The adequate stimulus to the lateral line organ is motion of the water relative to the body, arising from nearby hydrodynamic sources. Several peripheral steps in lateral line signal transduction have been physiologically identified(reviewed in Dijkgraaf, 1963; Bleckmann, 1993; Coombs et al., 2000; Coombs and van Netten, 2006),and biophysical models exist that accurately describe the hydrodynamic and mechanical properties of individual sensory units (reviewed in Kalmijn, 1989; van Netten, 2006). To date,only a limited number of investigations have been performed to understand how the information on distance of a vibrating source is represented in the overall excitation pattern along an array of neuromasts in the lateral line canal (e.g. Denton and Gray,1982; Denton and Gray,1983; Hassan,1993; Coombs et al.,1996; Coombs and Conley,1997a; Coombs and Conley,1997b). A precise description, together with a quantitative interpretation, of such measured patterns that allows a reconstruction of the location and vibration direction of vibrating sources to be made is still lacking.
The lateral line organ plays a key role in the detection of vibrating obstacles, both on and under the water surface (e.g. Harris and van Bergeijk, 1962; Dijkgraaf, 1963; Bleckmann and Topp, 1981; Kalmijn, 1989; Coombs and Janssen, 1990; Bleckmann, 1993; Claas and Münz, 1996; Coombs and Montgomery, 1999). The purposes of detecting and discerning moving objects in the surrounding water are diverse and noticeably include spotting prey, predators or mates. Electrophysiological and behavioural studies have shown that an animal, using its lateral line organ, can locate an object of interest within small distances (Dijkgraaf, 1963),comparable to its body length (Denton and Gray, 1983; Kalmijn,1988; Coombs and Conley,1997a; Coombs and Conley 1997b; Coombs et al.,2000). In addition, behavioural studies have clearly demonstrated that animals orient their bodies according to the stimulus. The route by which fish approach a vibrating source varies between a direct heading and more indirect trajectories such as zigzag or arched pathways and depends on the starting position of the prey (Hoekstra and Janssen, 1986; Coombs and Conley, 1997a).
Canals of the lateral line organ contain several neuromasts that are spatially distributed at more or less equidistant locations (e.g. Coombs et al., 1996). A single neuromast in a lateral line canal can be considered as an independent detector of the local flow pattern, because there is only minimal mechanical coupling between adjacent canal segments of fluid on either side of a neuromast(Sand, 1981; Denton and Gray, 1983; Tsang, 1997). Moreover, single neuromasts are selectively innervated by several neurons that do not connect to other neuromasts (Münz,1985), so that local flow information, detected by a single neuromast, is relayed to higher order neurons and is therefore available for further processing by the central nervous system (CNS)(Coombs et al., 1996).
Canal neuromasts consist of mechanosensory hair cells, covered by a gelatinous cupula that effectively transfers the motion of the fluid in the canal to the bundles of the hair cells. The directional sensitive hair cells in a neuromast are oriented with their hair bundles in opposite directions along the axis of the canal and therefore selectively detect the component of the flow field that is parallel or anti-parallel to the canal axis(Kuiper, 1956; Flock, 1965). In several studies of different fish species, it has been demonstrated that the responses of the hair cells of canal neuromasts are proportional to the acceleration of the water around the fish (Denton and Gray, 1983; Denton and Gray,1989; Coombs and Janssen,1990; Kroese and Schellart,1992; Wubbels,1992; Engelmann et al.,2000). Since under free-field conditions water acceleration is proportional to the pressure gradient, the individual neuromasts encode the pressure gradients along the fish's body, as has been directly demonstrated experimentally in the trunk lateral line canal organs of goldfish(Coombs et al., 1996). It is therefore appropriate to consider the collective system of neuromasts in a lateral line canal as an array of independent pressure-gradient detectors that collects information on the surrounding flow field and has the potential to effectively image the local flow field sources around an animal(Coombs et al., 1996; Coombs and Conley, 1997a; Coombs and Conley, 1997b).
Electrophysiological studies have shown that information about the location of a stimulus source is encoded in the extracellular receptor potentials(ERPs) arising from the mechano-transduction of the hair cells in a single neuromast (Harris and van Bergeijk,1962; Sand, 1981)as well as in the activity of fibres innervating the lateral line organs(Coombs et al., 1996; Coombs and Conley, 1997a). So far, no direct decoding schemes have been proposed to quantitatively interpret measured excitation patterns along the lateral line canal in terms of the position and direction of vibration of sources. In order to do so, in the present study we have measured the ERPs of canal neuromasts of the ruffe(Gymnocephalus cernuus) in response to a vibrating sphere and we have compared the results to theoretically predicted excitation patterns along a lateral line canal. Extracellular receptor potentials are suitable for this purpose because they can be routinely obtained and provide long and stable recordings that are necessary for mapping the associated receptive fields of a single neuromast. These quantitative results, together with the analytically modelled excitation patterns based on the properties of potential(irrotational) fluid flow past a vibrating sphere, show that the information on the sources is present in the form of a wavelet transform of the excitation pattern. This information uniquely identifies the distance and position of the sources along the lateral line, as well as their direction of vibration,within a range of roughly one fish body length. The implication of this is that the information obtained by a linear (1-D) array of detectors allows the fish to reconstruct the positions of several vibrating sources in a two-dimensional (2-D) space.
Methods and theory
Stimulus
In order to study the function of the lateral line in detecting the position and direction of motion of a vibrating stimulus source, ERPs were measured in response to a vibrating sphere. Fig. 1 shows a diagram of the stimulus geometry in relation to the fish. The position of the sphere in the x,y-plane with respect to the fish was changed in discrete steps. The step size Δx varied between 1 and 4 mm, and the step sizeΔ y was fixed at 5 mm; the error of both Δx andΔ y was less than 50 μm. The sphere was initially placed at a short distance from the canal, at a position that was visually estimated to be closest to the cupula. All subsequent sphere positions were referenced to the coordinates of this initial position. The actual distance of the sphere from the fish in the y-direction, d, was then varied with step size Δy and can be expressed as d=a+yE+nΔy,where a is the radius of the sphere, yE is an estimate of the initial distance between the edge of the sphere and the skin of the fish, and n is the (positive) number of discrete steps taken in the y-direction. To obtain excitation patterns, the source was displaced in the x-direction so that its position along the lateral line with respect to the neuromast, s, can be expressed as s=b+mΔx, where m is the(positive or negative) number of discrete steps taken in the x-direction (Fig. 1),and the initial shift of the source in the x-direction, b,was kept close to zero. The angle of the direction of vibration with respect to the lateral line (x-direction) is denoted by φ.
Schematic representation of the experimental setup. The horizontal x,y-plane is defined by an x-axis parallel to the lateral line, along which the position is denoted by s, and a laterally directed y-axis. A neuromast at position s is stimulated by a sphere placed at distance r and angle θ with respect to the x-axis. The distance of the sphere from the y-axis is denoted by b, and the distance from the x-axis (lateral line) by d. The sphere vibrates (double-arrowed bold line) at an angle φ relative to the x-axis, which corresponds to an angleγ between the axis of vibration and the vector pointing to the sphere position (r). For clearness, the geometry is depicted in relation to the trunk lateral line system. Actual measurements were done on the cephalic lateral line system.
Schematic representation of the experimental setup. The horizontal x,y-plane is defined by an x-axis parallel to the lateral line, along which the position is denoted by s, and a laterally directed y-axis. A neuromast at position s is stimulated by a sphere placed at distance r and angle θ with respect to the x-axis. The distance of the sphere from the y-axis is denoted by b, and the distance from the x-axis (lateral line) by d. The sphere vibrates (double-arrowed bold line) at an angle φ relative to the x-axis, which corresponds to an angleγ between the axis of vibration and the vector pointing to the sphere position (r). For clearness, the geometry is depicted in relation to the trunk lateral line system. Actual measurements were done on the cephalic lateral line system.
The hydrodynamic stimulus was produced by a Teflon sphere(Ø=2a=10 mm), which was attached via a stiff,insulated metal staff (Ø=4 mm) to a piezo-electric actuator (P-843.30;Physik Instrumente, Waldbronn, Germany) vibrating sinusoidally with a frequency of 65 or 70 Hz. These frequencies were chosen in order to evoke a cupular response in the acceleration-sensitive frequency range, well below the resonance frequency yet enabling the measurement of a clear receptor potential. The amplitudes of vibration were kept constant during a series of steps in the x-direction, but varied from 0.5 to 3.2 μm depending on the distance to the fish. The voltage applied to the piezo-electric driver was generated via a 16-bit digital–analogue (D–A)converter (DSP-16; Ariel, Highland Park, NJ, USA), so that the stimulus buffer contained 16 periods with 32 points per period. Responses were averaged corresponding to 180 stimulus buffers.
The sphere was adjusted to vibrate in a direction approximately parallel to the canal. It should be noted that, due to the refraction of light at the interface of water and air and due to the fact that the canal was covered by skin, the direction of vibration could only be roughly estimated and thus, in practice, the sphere could vibrate at angles (φ) up to approximately 10° with respect to the canal axis (x-direction).
Preparation and measurements of extracellular receptor potentials(ERPs)
Ruffe (Gymnocephalus cernuus L.) with body lengths ranging from 10 to 13 cm were anaesthetised with an intraperitoneal injection of Saffan(Mallinckrodt Veterinary, Uxbridge, UK) at a concentration of 60 mg kg–1 body mass. Animal procedures conformed to Dutch governmental rules and the guidelines of the University of Groningen Institutional Animal Committee (RuG-DEC). The fish were placed in a large water tank (base, 50×25 cm; height, 17 cm) at a depth of 2–2.5 cm below the water surface. They were respired by a flow of tapwater through their gills and held in place by body clamps. Measurements were performed on neuromast no. 3 (Jakubowski,1963) in the supraorbital lateral line of the fish. The cupula of this neuromast is enclosed in the canal by a bony bridge, while the canal is covered by skin. A small incision was made in the skin covering the canal next to the bony bridge to allow the placement of a silver wire electrode(Ø=0.03 mm) in the canal for measuring ERPs. The electrode was insulated except at the tip, enabling measurements of potentials from the small region around the tip, which was placed in the vicinity of the cupula. A chloridised silver reference electrode was placed in the trunk of the fish. Both electrodes were connected to a differential preamplifier (PreAmp 113;EG&G, PARC, Princeton, NJ, USA) with a band pass of 0.3–3 kHz. The signal was further low-pass filtered [elliptic 16-pole filter (DIFA, Breda,The Netherlands); cut-off at 16× the stimulus frequency], amplified and stored via a 16-bit analogue–digital (A–D) converter(DSP-16; Ariel). The sampling frequency was 32× the sinusoidal stimulus frequency. The amplitude of the ERP, the main component of which is at twice the stimulus frequency (Kuiper,1956), was obtained by calculating a fast Fourier transform (FFT)of the recorded ERP time traces and extracting the amplitude and phase of the component at 2f (130 or 140 Hz) for each discrete location of the sphere.
Theoretical pressure gradient patterns and wavelets
Canal lateral line responses are proportional to the acceleration of the external water (Denton and Gray,1983; Coombs and Janssen,1990; Kroese and Schellart,1992), which, in turn, under free-field conditions, is proportional to the pressure gradient (e.g. Kalmijn, 1988; van Netten, 2006). The displacement of the neuromasts in a lateral line canal is therefore proportional to the local pressure gradient along the lateral line(Denton and Gray, 1983; Coombs et al., 1996).
(A) The even dipole wavelet function, Ψe, as a function of position along the lateral line, s, for two values of the source distance d (10 mm, solid line; 20 mm, broken line) as indicated. The shift factor b=0 mm. (B) The odd dipole wavelet function,Ψ o, for two values of the source distance d (10 mm,solid line; 20 mm, broken line) and with shift factor b=0 mm. D denotes the distance between the two extremes. (C) The linear combination of the even and odd wavelets for φ=8°, for two values of the source distance d (10 mm, solid line; 20 mm, broken line) and b=0 mm. S denotes the distance along the lateral line between the zero crossings (A,C).
(A) The even dipole wavelet function, Ψe, as a function of position along the lateral line, s, for two values of the source distance d (10 mm, solid line; 20 mm, broken line) as indicated. The shift factor b=0 mm. (B) The odd dipole wavelet function,Ψ o, for two values of the source distance d (10 mm,solid line; 20 mm, broken line) and with shift factor b=0 mm. D denotes the distance between the two extremes. (C) The linear combination of the even and odd wavelets for φ=8°, for two values of the source distance d (10 mm, solid line; 20 mm, broken line) and b=0 mm. S denotes the distance along the lateral line between the zero crossings (A,C).
Fitting measured excitation patterns
Fig. 4 shows an example of a fit made with Eqn 4 to measurements of ERPs as a function of position s. It should be noted that the nonlinear transfer function does not affect the positions of the zero-crossings of pressure gradient excitation patterns but merely produces local minima at these positions in the rectified response of the pressure gradient patterns as can be illustrated by comparing Fig. 3E with Fig. 2C. Fig. 3E was constructed from Fig. 2C by applying the nonlinear transfer function (Eqn 4) depicted in Fig. 3D. The phase of the pressure gradient shifts by 180° on passing a zero-crossing, as is also evident from recordings of afferent fibres(Coombs et al., 1996). Since the measured ERPs are effectively rectified versions of the pressure gradients, the direction of the pressure gradient is not coded in the ERP,with the consequence that the 180° phase-shifts at zero crossings are not seen in ERP recordings, as is clear from Fig. 4B.
(A) Stimulus signal as a function of time, with a frequency, f=65 Hz. (B) Extracellular receptor potential (ERP) of a neuromast as a function of time measured in response to the signal shown in A. (C) Spectrum of the ERP response depicted in B showing the amplitude components as a function of frequency. The component at twice the stimulus frequency (2f=130 Hz)clearly dominates the fundamental component (f=65 Hz) and is taken as the ERP amplitude. (D) Measured amplitude of the ERP (2f component)as a function of cupular displacement (data points taken from van Netten, 1987). The non-linear model (solid line) is given by Eqn 4, with fitted parameters g=37±3, n=1.7±0.2 and c=34±2.(E) ERP as a function of location along the lateral line s, simulated using the nonlinear function (Eqn 4) depicted in D, applied to the pressure gradient profile calculated from the linear combination of the wavelets shown in Fig. 2C (d=10 mm),corresponding to φ=8°. S denotes the distance between the zeros, and u is given by Eqn 4.
(A) Stimulus signal as a function of time, with a frequency, f=65 Hz. (B) Extracellular receptor potential (ERP) of a neuromast as a function of time measured in response to the signal shown in A. (C) Spectrum of the ERP response depicted in B showing the amplitude components as a function of frequency. The component at twice the stimulus frequency (2f=130 Hz)clearly dominates the fundamental component (f=65 Hz) and is taken as the ERP amplitude. (D) Measured amplitude of the ERP (2f component)as a function of cupular displacement (data points taken from van Netten, 1987). The non-linear model (solid line) is given by Eqn 4, with fitted parameters g=37±3, n=1.7±0.2 and c=34±2.(E) ERP as a function of location along the lateral line s, simulated using the nonlinear function (Eqn 4) depicted in D, applied to the pressure gradient profile calculated from the linear combination of the wavelets shown in Fig. 2C (d=10 mm),corresponding to φ=8°. S denotes the distance between the zeros, and u is given by Eqn 4.
Results
Experimental quantification of linear relationship between spatial variation in pressure gradient and source distance
ERPs of single neuromasts in the supraorbital canal of Gymnocephalus cernuus (N=11) were measured to obtain quantitative information on the excitation pattern of neuromasts along the canal, as evoked by a vibrating sphere. ERPs are produced by evoked transducer currents of the hair cells underlying a neuromast and are a direct measure of the mechanical displacements of a neuromast's cupula (e.g. Corey and Hudspeth, 1983; Wiersinga-Post and van Netten,1998) (see also Methods and theory). Since cupular displacement is proportional to the external water acceleration in the approximate frequency range of 10–100 Hz (van Netten,2006), ERPs are thus proportional to pressure gradients at these frequencies (see Methods and theory). Instead of measuring the responses of several neighbouring neuromasts, excitation patterns (cf. Fig. 4A) were obtained by varying the position of the stimulus sphere in the x-direction (e.g. Coombs et al., 1996). The sphere was submerged slightly above the canal, and its position was changed in discrete steps along the x-axis at several experimentally controlled distances (d) in the y-direction (see Fig. 1). Results were plotted for each distance, d, as a function of position, s, along the lateral line canal, producing an excitation pattern.
(A) Measured amplitude of extracellular receptor potentials (ERPs; circles)from a neuromast in the supraorbital lateral line of the ruffe. The sphere was moved along an axis parallel to the lateral line (x-axis) at a distance d=10 mm. This is referred to as an excitation pattern (see text). ERPs were fitted with the model given by Eqn 4 (solid line), describing the measured excitation patterns (b=–0.9±0.2 mm; d′=8.5±0.3 mm; φ=–9±3°). (B) Phase of ERPs.
(A) Measured amplitude of extracellular receptor potentials (ERPs; circles)from a neuromast in the supraorbital lateral line of the ruffe. The sphere was moved along an axis parallel to the lateral line (x-axis) at a distance d=10 mm. This is referred to as an excitation pattern (see text). ERPs were fitted with the model given by Eqn 4 (solid line), describing the measured excitation patterns (b=–0.9±0.2 mm; d′=8.5±0.3 mm; φ=–9±3°). (B) Phase of ERPs.
A typical example of an excitation pattern measured at a distance of d=10 mm is shown in Fig. 4 (data points) together with a theoretical fit using Eqn 4 combined with Eqn 2a (Fig. 4,solid line). The measured amplitudes in this example clearly peak at approximately s=0 mm, which corresponds to a sphere vibrating directly next to the cupula. The centre of the peak as determined from the fitted response appears to be at b=–0.9±0.2 mm. As the experiments were performed on neuromasts in unexposed canals, it was difficult to exactly determine the position of the cupula underneath the skin.
Therefore, the centre of the peak is often slightly displaced from s=0 mm as indicated by the parameter b from the fit.
The width of the peak, measured between the points where the amplitudes reach minimum values, is S=12.5 mm. The distance d′obtained from the fitted curve is 8.5±0.3 mm, while Eqn 3a, using S=12.5 mm, yields 8.8 mm. On each side of the central peak there is a smaller peak, the height of the left-hand peak being greater than that of the right-hand one. This difference in height can be attributed to a non-zero angle φ between the lateral line canal and the direction in which the stimulating sphere is vibrating, so that a minor contribution of the odd wavelet is required to fit the data (see Eqn 2; Fig. 4;φ=–9±3°). Although we tried to adjust the vibration axis of the sphere to be parallel to the longitudinal direction of the canal, exact alignment was not always successful and usually a small, non-zero angle φwas obtained from the fits. Fig. 4B presents the measured phase of the ERPs for the component at twice the stimulus frequency. It is clear that the phase is fairly constant and close to 180° along the x-axis, although small changes of up to 45° are apparent at the same positions as where the minima appear on either side of the highest peak. Similar phase changes around the minima occur in most of the measured responses.
The characteristic three-peak shape of the ERP amplitudes for small anglesφ of sphere vibration direction to the lateral line canal is maintained on varying the distance between the source and the lateral line, but the width of the peak increases with distance. Fig. 5 demonstrates this property for two different neuromasts. Since the amplitude of the response decreases rapidly with the cube of the distance(see Eqn 2b), for larger distances we tried in most cases to compensate by increasing the displacement amplitude of the sphere. Therefore, the ERP excitation patterns measured at different distances are similar in amplitude,enabling the fitting of the model (Eqn 4) and to extract parameters with comparable accuracy. It was experimentally verified that increasing the sphere's stimulus amplitude does not affect the positions of the local minima of the ERP, which are the important features of the measured excitation patterns determining the fitted value d′.
In the examples shown in Fig. 5, the increase in peak width with source distance is clearly linear, as indicated by the straight broken lines that connect the minima(i.e. pressure gradient zero-crossings) of three different excitation patterns displayed at vertically equidistant offsets. The peak width is thus proportional to the experimentally controlled distance d. This is in line with theory, which predicts a linear increase of the separation, S, of the minima with increasing distance, d (Eqn 3a).
To further test the theoretical hypothesis of the linear relationship between the spatial variations in the excitation patterns and the experimentally controlled distance d, we compared values of d to the fitted distance parameter d′. Fig. 6 shows fitted distance d′ as a function of controlled distance d for different neuromasts (N=9). A linear fit according to d′=Aid+Bi was performed on each neuromast (i=1–9). r2values of these fits all exceeded 0.96, supporting the hypothesized linear relationship. The coefficients Ai and Bi obtained from all neuromasts were averaged with weight factors taking the errors into account, yielding the values Aav=1.07±0.01 and Bav=–0.5±0.1 mm. The associated function d′=Aavd+Bav is plotted in the same figure (bold solid line). Fitting a linear function to the pooled data of all fish gave similar values (A=0.97±0.12; B=–0.7±1.6 mm). For comparison, a line through the origin with a slope of one (i.e. d=d′) has been added(broken line). Together, these results firmly show the equality of experimentally controlled distance, d, and the spatial characteristics of the measured excitation patterns along the lateral line,characterised by d′.
Measured excitation patterns (circles) obtained from two cupulae (A,B) with model fits (solid lines) for three different distances, d, of the stimulus sphere along the y-axis. (A) Distances d from bottom to top are 7, 12 and 17 mm. (B) Distances d from bottom to top are 10, 15 and 20 mm. Broken lines in both panels are fairly well intersecting the zeros of the extracellular receptor potentials (ERPs) (indicated by crosses on the equidistant x-axes) and therefore illustrate the linear widening (S; Eqn 3a) of the excitation patterns with increasing distance d.
Measured excitation patterns (circles) obtained from two cupulae (A,B) with model fits (solid lines) for three different distances, d, of the stimulus sphere along the y-axis. (A) Distances d from bottom to top are 7, 12 and 17 mm. (B) Distances d from bottom to top are 10, 15 and 20 mm. Broken lines in both panels are fairly well intersecting the zeros of the extracellular receptor potentials (ERPs) (indicated by crosses on the equidistant x-axes) and therefore illustrate the linear widening (S; Eqn 3a) of the excitation patterns with increasing distance d.
Dipole imaging using the continuous wavelet transform
The linear relationship between the source distance, d, and the spatial variations of pressure gradient excitation patterns, characterised by scale parameter, d′, allows for an interesting and general quantitative image-reconstruction of dipole sources positions and their direction of vibration. This analysis is based on a general technique known as the continuous wavelet transform (CWT). The CWT is related to the property that a function, under certain conditions, can be represented by a weighted series of scaleable base functions, or mother wavelets (e.g. Mallat, 1998). The two dipole wavelets defined by Eqn 2c,d fulfil this essential feature of mother wavelets,since they are linearly scaled by the distance parameter d. In addition, mother wavelets require a second parameter, which indicates a shift of the wavelet along the x-axis. Also, this parameter is defined for the dipole wavelets via b (Eqn 2c,d).
The distance d′ obtained from the model (Eqn 4) fitted to the measured excitation patterns for N=9 neuromasts (various symbols)as a function of the real distance d. The thick solid line indicates the linear fit d′=Aavd+Bav,with parameters Aav=1.07±0.01 and Bav=–0.5±0.1 mm. For comparison, the broken line illustrates the case d′=d (A=1 and B=0 mm).
The distance d′ obtained from the model (Eqn 4) fitted to the measured excitation patterns for N=9 neuromasts (various symbols)as a function of the real distance d. The thick solid line indicates the linear fit d′=Aavd+Bav,with parameters Aav=1.07±0.01 and Bav=–0.5±0.1 mm. For comparison, the broken line illustrates the case d′=d (A=1 and B=0 mm).
The CWTs, Fe,o(b,d), effectively form images of the dipole sources in the cylindrically symmetric 2-D b,d-plane around the lateral line along which a pressure gradient f(s)is produced. This 2-D space is related to the original x,y-plane(Fig. 1), so that the b-direction corresponds with the x-direction and the d-direction with the y-direction. If a source is located in the x,y-plane at a certain position, it shows up as a maximum of the CWT at the same location in the b,d-plane. Fig. 7 gives examples of contour plots of CWTs that effectively image dipoles located close to(Fig. 7A) or more distant from(Fig. 7B) the lateral line. These CWTs were obtained by applying Eqn 5 to theoretical pressure gradient profiles f(s) (indicated below the CWT contour-plots) of dipoles vibrating in a direction parallel to the lateral line at locations indicated by white crosses in the CWT contour-plot. Fig. 7A,B clearly shows that the CWT analysis technique produces reliable determinations of the locations of the dipole sources by peaking at the location of the sources (white crosses). The peaks have a more elongated shape in the y-direction than in the x-direction. In addition, the shape is asymmetrical in the y-direction, so that the decline with distance from the maximum is more gradual at more remote locations. Related to this observation is that the wavelets do not form an orthogonal set of base functions; there is thus redundancy in the reconstruction in terms of individual wavelet components. This results in spatial maps in the form of peaked distributions rather than discrete peaks at the source location.
If the envelopes of excitation patterns produced by several dipole sources not too close to each other are combined, the CWT-reconstruction may resolve these multiple sources, as is shown for two sources in Fig. 7C. This is even possible if they are located in front of each other(Fig. 7D). In the latter case,the CWT image of the sources is distorted in such a way that the peaks seem to attract each other, so that the distance between the sources is underestimated. The CWTs obtained with the even and odd mother wavelet may, in addition to the sources' positions, also provide their vibration directions,φ, via the CWT ratio, which is proportional to tanφ (cf. Eqn 2a).
Discussion
We have measured and analytically modelled excitation patterns along a lateral line canal and quantitatively compared the results. Previous lateral line studies that also showed the dependence of spatial variations of lateral line excitation patterns on source distance have been limited to a more general interpretation, without quantitative decoding of the source distance and angle of vibration. We show here that the excitation patterns have characteristic shapes that can be described by a family of wavelet patterns with a linear spatial scale factor, d (see Eqn 2), which is equal to the distance between the source and the lateral line. This straightforward linear relationship between spatial variation in the excitation patterns and source distance allows for an unambiguous absolute coding of the source distance in a linear lateral line array. This spatial coding is very robust as it is not dependent on the characteristics of the source, such as intensity,frequency of vibration, or dimensions, nor does it rely on specific fluid properties, such as density and viscosity. These characteristics also naturally link the specific physiological features of the two direction-sensitive groups of hair cells to the operational range of the lateral line canal organ, which is typically defined as a fish's body length(Denton and Gray, 1983; Kalmijn, 1988; Coombs and Conley, 1997a). Before elaborating on the implications of the observed linear spatial coding of source position by the lateral line organ, we will first discuss the conditions under which the present measurements and modelling were performed and their more general relevance for excitation of the lateral line organ.
Continuous wavelet transforms (2D-contour maps) calculated using Eqn 5 from pressure gradient excitation profiles [f(s), red curves below each contour map] associated with one (A,B) or two (C,D) dipole sources. The column to the right of each contour map quantifies the contour colours. Pressure gradient profiles were obtained using a single wavelet function defined by Eqn 2c. For the case of two sources (C,D), the pressure gradient was determined as the sum of two individual wavelet functions. The white crosses in the contour maps indicate the positions of the dipole sources in x,y-space and correlate adequately with the maxima of the contour plots in b,d-space (A–C). If the sources are aligned with a fixed y-coordinate (D), the maxima seem to attract each other.
Continuous wavelet transforms (2D-contour maps) calculated using Eqn 5 from pressure gradient excitation profiles [f(s), red curves below each contour map] associated with one (A,B) or two (C,D) dipole sources. The column to the right of each contour map quantifies the contour colours. Pressure gradient profiles were obtained using a single wavelet function defined by Eqn 2c. For the case of two sources (C,D), the pressure gradient was determined as the sum of two individual wavelet functions. The white crosses in the contour maps indicate the positions of the dipole sources in x,y-space and correlate adequately with the maxima of the contour plots in b,d-space (A–C). If the sources are aligned with a fixed y-coordinate (D), the maxima seem to attract each other.
Relevance of dipole sources
The use of a vibrating sphere in lateral line experiments is convenient since the hydrodynamic near-field produced by the sphere can be accurately controlled and predicted. It has been shown that several types of natural stimuli can be well approximated by the sinusoidal vibration of a sphere, or dipole source. Kalmijn discussed relevant stimuli to the lateral line,describing the dipole term of the stimulus as the leading term in a series expansion of general water flow generated by moving sources that do not change their dimensions (Kalmijn,1988). The relevance of vibrating objects for stimulating the lateral line is supported by several experimental reports. Montgomery and Macdonald recorded the vibrations of water produced by swimming planktonic prey (Montgomery and Macdonald,1987). They showed that these vibrations exhibited low-frequency peaks at 3–6 Hz, several harmonics of the fundamental frequency, and strong peaks between 30 and 40 Hz that were detected by the lateral line organ. Bleckmann et al. measured sinusoidal water motion in the vicinity of hovering fish and crustaceans (Bleckmann et al., 1991). Coombs and Janssen induced a feeding response in fish by the use of a vibrating sphere at 50 Hz(Coombs and Janssen, 1990). Satou et al. demonstrated that the lateral line is involved in inter-sexual communication in the himé salmon (Oncorhynchus nerka) by showing that a spawning response was induced by a sphere vibrating at 21 Hz(Satou et al., 1994). The effect of the presence of the fish in distorting a dipole field has been investigated both theoretically (Hassan,1993) and experimentally(Coombs et al., 1996), and it was shown to result in somewhat higher amplitudes but with minimal effect on the spatial characteristics of excitation patterns.
Suitability of ERPs of a single neuromast to analyse excitation patterns of pressure gradients along a lateral line canal
ERPs of supraorbital canal neuromasts were measured in response to sinusoidally varying displacements of water produced by a sphere. The position of the sphere was changed along a line parallel to the lateral line canal at a fixed distance (d), allowing the differences to be observed in both amplitude and phase of the ERPs arising from these different source locations. This method of using responses of a single neuromast to simulate the excitation pattern of a fixed vibrating sphere that would arise along an array of neuromasts lined up in the lateral line canal has been used previously(e.g. Coombs et al., 1996; Coombs and Conley, 1997a). In the present series of experiments, ERPs were used as a monitor of cupular displacement. The displacement was not measured directly, as has been done previously (van Netten and Kroese,1987; Wiersinga-Post and van Netten, 2000; Ćurčić and van Netten, 2005). ERPs are relatively easy to measure and require minimal invasive interference with canal and cupular hydrodynamics, since only a small incision in the skin close to a neuromast is required for the placement of a thin wire electrode. ERPs thus provide hours of stable recordings, which are required in order to obtain information on the excitation pattern with sufficient accuracy for the present quantitative analysis. The ERP increases monotonically with cupular motion(Fig. 3D) and is a rectified measure of cupular displacement, since the opposite groups of directionally sensitive hair cells beneath a neuromast are fairly evenly represented(Rouse and Pickles, 1991). This leads to an ERP phase ambiguity of 180°. Minima in a pressure gradient profile (Fig. 2C) are thus rectified to ERP maxima (cf. Fig. 3E), while zero crossings of the pressure gradient correlate with ERP minima. These ERP minima thus indicate a phase reversal of the pressure gradient; and their separation along the lateral line, S, is a sensitive and linear measure of the wavelet scaling parameter, d (Eqn 3e), which is not affected by the rectifying properties of the ERP. The information on distance of the source, as transduced by the two populations of hair cells and subsequently transmitted to the CNS, is thus clearly reflected in the spatial characteristics of the ERP (e.g. Fig. 3E). We can consequently use the ERPs to analyse the spatial encoding in an array of lateral line neuromasts.
Encoding of source location and direction of vibration
One of the most important questions related to source localisation by fish is how excitation patterns along the array of lateral line neuromasts can be analysed and resolved into information about the source distance. Coombs and Conley, in their behavioural experiments on mottled sculpin (Cottus bairdi) (Coombs and Conley,1997b), described several types of approach to a vibrating source that simulates prey. The approach strategy of the fish depended on its initial position with respect to the stimuli. According to these authors, the fish approaches the prey along a direct route only when the prey is to the side of the fish at the onset of the stimuli. They also describe a so-called arching pattern of approach that seems to follow iso-pressure lines and occurs mainly when the fish is facing the source and at 90° relative to the axis of the vibration. A zigzag pattern of approach was observed when the fish was pointing at an angle of 45° to the source. From these observations, it can be speculated that a fish might not be able to determine the location of the source in all circumstances, and it will therefore orient its body with respect to the source in order to gain the most information.
In cases where the source vibrates in a direction parallel to the lateral line, our present analysis shows that a relatively simple strategy might work. In this situation φ=0°, so that the pressure gradient consists only of the even wavelet function. The pressure gradient peaks at the location of the source in the x-direction. The distance of the source in the y-direction is then simply related to the separation between the pressure gradient zero-crossings, S, according to
The situation becomes more complicated when φ increases beyond 20°. The symmetry of the three peaks in the excitation pattern changes and the main peak is no longer situated at the x-component of the source(Fig. 1). In fact, at increasing angles, one of the side-maxima becomes smaller and practically disappears. If the vibration occurs at 90° to the lateral line in the x,y-plane, a symmetric pattern appears again with one pressure gradient zero-crossing in between a symmetrically located maximum and minimum. The separation, D, between these two extremes is identical to the source distance (i.e. d=D; Eqn 3b).
It can be shown that the error in this estimate of the x-coordinate is always less than 5% of the (real) source distance, d, independent of φ.
The CWT analysis presented here is a more general technique that can be applied if the axes of vibration are not known and if multiple sources contribute to an excitation pattern. It is somewhat more elaborate than the estimates just discussed, but it effectively produces a complete 2-D image of the sources present in the space around a lateral line. The ratio of the reconstructions based on the even and odd mother wavelets may give the angle of vibration, φ. However, it is not known whether neural stages of lateral line signal processing exist in which correlates of the scaled convolution-like algorithm (Eqn 5) are performed. Convolution-like processing or the cross-correlating of signals has been incorporated in models of direction detection by the superficial lateral line system(Franosch et al., 2003) and,in combination with neural delay lines, in models of directional hearing(Knudsen et al., 1987).
A general statement that can be made on the basis of the CWT reconstruction is that a fish, by observing a one-dimensional pressure gradient pattern along its lateral line, in principle has the information necessary to determine the position of sources and their axes of vibration in a 2-D plane through the lateral line canal. This extension from one to two dimensions is made fundamentally possible by the restrictions of the hydrodynamic field having properties of (potential) flow. This gives rise to the linear relationship between the source distance and the spatial scaling factor d. A combination of differently oriented lateral lines, which are found in particular on the head (Coombs et al.,1988; Webb, 1989),will therefore allow for another dimensional extension, resulting in an effective local 3-D reconstruction of source locations.
Accuracy and operational range of source position detection
It is possible to derive an interesting upper limit on the operational range within which the parameter d, and therefore the distance of a source, can be decoded, if the coding relies on the detection of phase reversal in the excitation patterns. It has been suggested(Coombs et al., 1996) that the lateral line system, with its two morphological populations of directionally sensitive hair cells, is ideally equipped for such a task. The largest distance between two phase reversals in an array of lateral line detectors is limited to its overall length L and imposes a maximum on the operational detection range of
Thus far, only continuous pressure gradient profiles have been considered. In the lateral line canal, pressure gradient profiles are sampled at the discrete positions where neuromasts are present. The related sampling distance, or inter-neuromast distance, Dn, thus imposes limits on the accuracy with which the position of a source can be detected. The spatial frequencies of the dipole wavelets scale inversely with the distance of the source to the lateral line, d. Taking 2/d as the spatial frequency bandwidth of a wavelet produced by a source at a distance d, a range in which most of its energy appears to be contained, Nyquist's criterion requires a sampling distance of d/2 or less to reliably detect the spatial characteristics of this wavelet. This means that a source, to be correctly detected, should not be closer than approximately twice the inter-neuromast distance Dn. Relative short stretches of lateral line canals in different orientations found on the head are therefore expected to enable mapping of a 3-D space limited to the region close to the head and mouth, and with a resolution determined by the neuromast density.
The present analysis has been based on the detection of pressure gradients along linear arrays. Lateral line arrays usually have some curvature,depending on their location. For the trunk lateral line this is most likely causing only small deviations, but shorter lateral line canals, such as those on the animal's head usually have more curvature, which will likely affect the accuracy of the results of a CWT-analysis, as presented. Nevertheless, the strongest variations in pressure gradients will occur at the neuromasts along the lateral line closest to the source, which in a CWT-like analysis provide the dominant information on the source position along the array.
In conclusion, dipole sources vibrating with sufficient amplitude can be detected if their distance, d, lies within a range having a lower limit determined by twice the inter-neuromast distance and an upper limit of the order of the length of the lateral line canal,
Acknowledgements
The authors thank D. G. Stavenga, G. R. Blake, C. J. M. Meulenberg and A. B. A. Kroese for their comments on previous versions of the manuscript. B.C.-B. was supported by the School of Behavioural and Cognitive Neurosciences(BCN, University of Groningen).