Heart rate can be telemetered from fish using FM radio transmitters (Nomura & Ibaraki, 1969), FM acoustic transmitters (Wardle & Kanwisher, 1974), acoustic pulsed transmitters (Priede & Young, 1977), electromagnetic transmitters (Priede et al. 1985) and acoustic transponders (Storeton-West et al. 1978). Most of these systems transmit only over short distances or cannot be used with the standard equipment used in animal-tracking studies. This paper describes an acoustic transmitter which emits a high-power pulse triggered by the R wave of the electrocardiogram (ECG) and is compatible with normal field equipment for tracking fish.

The design is based on the concept of Priede & Young (1977) but has a 75 kHz output usable in fresh or salt water, modern integrated circuits with low power consumptions, and lithium batteries. The circuit (Fig. 1A) is made on a miniature printed circuit board using chip-type surface-mounting components. Power is provided by a two-cell lithium battery (Duracell PX28L) which is centre-tapped to provide a nominal ±3V supply. For safety reasons, care should be taken not to heat the battery excessively during soldering. One input is connected to the earth (IP2) and the other to IP1. Al amplifies the ECG signal. Cl in the feedback circuit filters out most high-frequency noise such as muscle activity. C2 provides a.c.-coupling to the second amplifier stage A2. Values of Cl and C2 can be adjusted for different rise-times of ECGs of fish living at different temperatures. A3 is configured as a comparator, the output of which changes polarity whenever the input exceeds a threshold set by adjusting R9. A negative-going transition triggers a pulse from the acoustic output stage of 5 ms duration at 75 kHz and source level 174dB re 1 μPa at 1 m.

Fig. 1.

(A) Circuit diagram. A1,A2,A3, amplifiers (ICL7611, Intersil); power connections on the amplifiers are not shown, positive pin 7, negative pin 4, pin 8 (Iq set) normally connected to positive (see Intersil manuals). AOP, acoustic output module. Cl, 1000pF; C2, 4-7μF; IP1,IP2, electrode inputs; R1,R2, 100K; R3, IM; R4,R5, 10K; R6, 33OK; R7,R8, 220K; R9, 470K linear potentiometer Siegert TPHG; R10,Rll, 10K. All components are surface-mounted leadless-chip types. (B) Transmitter mounting. The acoustic heart-rate transmitter was held by a foam saddle which was sutured to the dorsal surface of the fish. Leads were connected to ventrally implanted electrodes which detected the electrocardiogram.

Fig. 1.

(A) Circuit diagram. A1,A2,A3, amplifiers (ICL7611, Intersil); power connections on the amplifiers are not shown, positive pin 7, negative pin 4, pin 8 (Iq set) normally connected to positive (see Intersil manuals). AOP, acoustic output module. Cl, 1000pF; C2, 4-7μF; IP1,IP2, electrode inputs; R1,R2, 100K; R3, IM; R4,R5, 10K; R6, 33OK; R7,R8, 220K; R9, 470K linear potentiometer Siegert TPHG; R10,Rll, 10K. All components are surface-mounted leadless-chip types. (B) Transmitter mounting. The acoustic heart-rate transmitter was held by a foam saddle which was sutured to the dorsal surface of the fish. Leads were connected to ventrally implanted electrodes which detected the electrocardiogram.

The circuit was enclosed in a polypropylene tube (52 mm long, 16 mm diameter) filled with oil to protect the components and provide acoustic coupling to the surrounding water. The mass in air was 19 g and life under test at 60 beats min−1 was 28 days. The PVC-insulated electrode leads (RS Components 357-154) were threaded through a flexible rubber seal in the end of the casing using a hypodermic needle. The transmitter was mounted on a flexible neoprene foam saddle (Fig. IB) which, on pike, was sutured in a medial position on the anterior dorsal surface by four sutures (Ethicon W328), one at each corner. Removal of one or two scales at each suturing site was necessary. The ECG electrodes were epoxy-insulated stainless-steel wires (0·8 mm diameter) bared at the tips and held in position with sutures, ventrally, close to the heart. Optimum lengths (cm) of the electrode leads for pike were: signal lead 0·029L+3·88, reference lead 0·023L+2·89, where L is fish fork-length (in cm).

Field trials with the transmitter were carried out at Loch Kinord (57°05′N, 2°55′W). Pike were caught by angling and allowed to recover in aerated water before being anaesthetized in benzocaine (lmg1−1) for attachment of the transmitter. R9 was adjusted so that the transmitter was triggered from the R wave of the ECG. Triggering from other components of the ECG was permitted since amplitude of the pike ECG normally declined following recovery from anaesthesia.

Fish were released close to the point of capture and were followed from boats using a conventional directional hydrophone and acoustic receiver (Mariner, Lowestoft, M471). The audio output of the receiver was recorded on one track of a stereo cassette tape (Sony WM6D crystal-control tape-speed) with a voice commentary and time record on the other track. Alternatively, real-time data could be relayed to shore via a radio buoy. The buoy could either be used by the mobile tracking team or, anchored near the fish, could operate remotely by detecting transmitter output via an integral omnidirectional hydrophone and acoustic receiver. Recording could thus take place on shore, and during periods when the fish was relatively inactive there was no need for a crew to remain on the water.

The range of the transmitter was about 500 m radius depending on water conditions. Within 12h following release the heart rate settled to apparently normal levels (Armstrong, 1987). Bursts of activity by the fish, accompanied by increased electromyogram (EMG) activity, often caused multiple triggering of the transmitter. This tended to reduce the transmitter life to about half that expected from laboratory tests.

Short-term oscillations in heart rate were recognizable as shown in Fig. 2A for an 800g pike at 03.00h on 12 January 1988. This heart-rate variability signal (HRVS) is often found in quiescent resting vertebrates and can be analysed to help understand cardiac control mechanisms (Armstrong et al. 1989). The low heart rate with a distinct HRVS serves to indicate that telemetry can provide observations from unstressed pike in the wild.

Fig. 2.

(A) The heart rate record of a resting pike at night. Heart rate was low with distinct oscillations evident around the mean level. (B) Reflex bradycardia or ‘approach reflex’. Heart rate declined markedly as a car approached the shore of the loch. (C) Heart rate change associated with a short burst of activity. Metabolic cost of activity was estimated by integration of heart beats above the baseline level (shaded area).

Fig. 2.

(A) The heart rate record of a resting pike at night. Heart rate was low with distinct oscillations evident around the mean level. (B) Reflex bradycardia or ‘approach reflex’. Heart rate declined markedly as a car approached the shore of the loch. (C) Heart rate change associated with a short burst of activity. Metabolic cost of activity was estimated by integration of heart beats above the baseline level (shaded area).

Two hours after release the heart rate was high and relatively uniform (Fig. 2B).

A distinct bradycardia was shown in response to a car approaching the loch near the fish. This ‘approach reflex’ (Labat, 1966) is the typical reaction to unusual stimuli and indicates normal levels of responsiveness by the fish to the environment.

Fig. 2C shows a tachycardia typical of that observed during an activity burst. It has been shown that there is a linear relationship between heart rate (fH) and oxygen consumption standardized to a 500 g pike: (Armstrong, 1986). This gives an estimate of the metabolic cost of this burst of 1·48 mg O2 which equates with the cost of swimming 34 m at 1 body lengths−1 or 9 m at 2 body lengths s−1. Often such bursts, confirmed by the presence of distinct EMG interference, could not be discerned using locational tracking. Heart-rate telemetry, therefore, revealed the presence and extent of localized, presumably foraging, movements that might otherwise be missed.

The new transmitter enables continuous field records of heart rate to be made in free-living fish in a range of environments. In fresh water, a VHF radio output (Armstrong et al. 1988) could be substituted for the acoustic output stage. This has a lower power consumption and other advantages.

We thank the numerous colleagues who assisted in the field, JDA and MCL acknowledge support of NERC and SERC studentships. LDV acknowledges the support of the Canary Government and the Caja General de Ahorros de Canarias.

Armstrong
,
J. D.
(
1986
).
Heart rate as an indicator of activity, metabolic rate, food intake and digestion in pike, Esox lucius
.
J. Fish Biol
.
29A
,
207
221
.
Armstrong
,
J. D.
(
1987
).
Metabolism, feeding and cardiac function in pike, Esox lucias
.
PhD thesis
,
University of Aberdeen
.
Armstrong
,
J. D.
,
De Vera
,
L.
&
Priede
,
I. G.
(
1989
).
Short-term oscillations in heart rate of teleost fishes: Esox lucias L. and Salmo trutta L
.
J. Physiol., Lond
.
409
,
41
.
Armstrong
,
J. D.
,
Lucas
,
M.
,
French
,
J.
,
Vera
,
L.
&
Priede
,
I. G.
(
1988
).
A combined radio and acoustic transmitter for fixing direction and range of freshwater fish (RAFIX)
.
J. Fish Biol
.
33
,
879
884
.
Labat
,
R.
(
1966
).
Electrocardiologie chez les poissons teleostéens: influence de quelques facteurs écologique
.
Ann. Limnol
.
2
,
1
175
.
Nomura
,
N. A.
&
Ibaraki
,
T.
(
1969
).
Electrocardiogram of the rainbow trout and its radio transmission
.
Jap. J. vet. Sci
.
31
,
135
137
.
Priede
,
I. G.
&
Young
,
A. H.
(
1977
).
The ultrasonic telemetry of cardiac rhythms of wild brown trout (Salmo trutta L.) as an indicator of bio-energetics and behaviour
.
J. Fish Biol
.
10
,
299
318
.
Priede
,
I. G.
,
French
,
J.
&
Duthie
,
G. G.
(
1985
).
Underwater acoustic and electromagnetic telemetry of the ECG of fish and other aquatic animals
.
Biotelemetry
8
,
387
390
.
Storeton-West
,
T. J.
,
Mitson
,
R. B.
&
Greer Walker
,
M.
(
1978
).
Fish heart rate telemetry in the open sea using sector scanning sonar
.
Biotelemetry
5
,
149
153
.
Wardle
,
C. S.
&
Kanwisher
,
J. W.
(
1974
).
The significance of heart rate in free swimming Gadus morhua′. some observations with ultrasonic tags
.
Mar. Behav. Physiol
.
2
,
311
324
.